Usun Model: At10-CO2 50-80 Bar High Pressure Air Liquified CO2 Pump for Closed Loop System

Usun Model: At10-CO2 50-80 Bar High Pressure Air Liquified CO2 Pump for Closed Loop System

Popular  CZPT Model :AT10-CO2  type  160mm pushed double performing Higher pressure air liquified CO2 pump for shut loop system  

CZPT Info for Air driven liquid pumps

 

CZPT air driven liquid  pumps are ratio gadgets that employ lower pressure compressed

 

air driving a greater diameter piston (region x pressure) which is linearly connected to a smaller sized

 

hydraulic piston/plunger. Using this ratio principal, a increased hydraulic strain can be produced.

 

CZPT Pump product figures reflect the pumps nominal force ratio, while the technical data 

 

indicates exact ratios.  The outlet stall pressure is straightforward to set by changing the air travel pressure

 

through a straightforward air pressure regulator. 

 

By multiplying the force ratio by the obtainable store

 

air pressure, the nominal liquid force can be calculated.

 

Exmple ( Pump Design: AT644 liquid pump)

 

Air travel piston region ( 160mm Ø)

 

CZPT plunger region ( 20 mm Ø)

 

True ratio = sixty four:one

 

one.  AIR Drive Segment

 

The air generate part consists of a gentle bodyweight piston complete with seals managing within an

 

aluminum barrel. The diameter of the air piston is 80mm. When compressed air is supplied to

 

the pump the air pushes the air piston down on a compression stroke

 

( forces fluid out of the liquid conclude).

 

 Under the control of pilot pins (poppet valve) activated at each finish of the stroke

 

two. CZPT Part (Wetted End)

 

The hydraulic section of an air pushed liquid pump is made up of 4 major parts, the hydraulic physique,

 

the piston/plunger, the examine valves and the primary high stress seal. The hydraulic

 

piston/plunger is  directly linked to the air piston and it is housed within the hydraulic physique and

 

its movement up and down produces the liquid movement into and out of the pump by means of the examine

 

valves. The verify valves are spring loaded and on the suction stroke the inlet examine valve

 

 opens to the maximum enabling fluid into the hydraulic entire body and on the compression stroke the

 

inlet check out valve closes and the discharge check valve opens forcing the pumped fluid into the

 

procedure. The principal large force seal is located within the hydraulic body and the piston/plunger seals

 

against this for the duration of operation. There are various resources and designs of large force seals

 

dependent on the fluid currently being pumped and the optimum pressures of the pump, nonetheless the

 

CZPT seals are suitable for equally h2o and hydraulic fluid use.

 

CZPT air driven liquid pumps are self-priming, Nevertheless, high ratio pumps are a lot more hard to

 

Prime and might call for bleeding. In basic, it is not recommended to use an air- line lubricator.

 

CZPT  air driven liquid pumps cycle automatically  as the outlet strain will increase the

 

resistance  also increases and the cycle charge decreases until finally the pump stops immediately

 

when the output  pressure forces are equal. This is referred to as the stall problem.

 

The pump will restart with a slight drop in the outlet strain or an increase in the air drive

 

strain. Pump overall performance can be influenced by a amount of circumstances, this sort of as freezing of the

 

exhaust muffler or pilot valves (which is triggered by dampness in air traces), insufficient inlet air-line

 

dimensions and soiled filers. When operating the pumps on a constant foundation, we recommend you use

 

a greatest cycle price of 50~60 cycles per moment.

 

This will both enhance services intervals and assist in avoiding ice forming

 

at the exhaust. An air offer dryer will also help in lowering icing up.

 

To acquire best overall overall performance, it is advised not to reduce the indicated port sizes

 

and consult We for stream situations not proven in charts.

Typical applications for  pneumatic pushed h2o testing pump  

Essential functions

One particular product available in 8 ratios

Compatibility with a assortment of liquids

Protected pneumatic procedure

Aluminum bodies and wetted supplies of carbon steel or stainless steel

Rugged,compact,trustworthy and straightforward maintenance verified layout

Substantial high quality seals, prolonged support daily life offered

No need for air line lubrication

Wide application with big range of strain ratio

Principal complex data 

Typical complex data for air pushed Liquified CO2 pumps  
 

AT Serial Air liquid pump 
CZPT data                                             Foundation on air pushed at 7Bar , air consumption is around  .9M3 for each min 
Base on air pushed force at 7Bar
Design Piston/Rod diameter ø(mm) Displacement for every stroke (mL) Liquid IN Liquid OUT Maximum outlet pressyre Bar@at eight.3Bar Liquid Outlet pressure (Bar)     1Bar=.1Mpa=1.019Kg/cm²
20 40 70 100 150 200 300 400 five hundred 600 seven-hundred 900 1200 1700 2350
Stream rate   L/min  (L/min)
AT10 50 294.fifty two NPT3/4” NPT3/4″ 83 35.34 26.fifty one twenty.sixty two 17.sixty seven 11.78                      
AT16 40 188.five NPT3/four” NPT3/four” 132.eight 22.sixty two sixteen.97 thirteen.2 11.31 seven.54                      
AT20 35 one hundred forty four.32 NPT3/four” NPT3/4″ 166 17.32 14.43 twelve.99 11.55 10.1                    
AT28 30 106.03 NPT1/2″ NPT1/two” 232.four 12.72 ten.six 9.54 eight.48 7.42 6.36                  
AT40 25 seventy three.sixty three NPT1/2″ NPT1/2″ 332 eight.84 7.36 six.sixty three 5.89 five.fifteen 4.forty two 3.68                
AT64 twenty forty seven.twelve NPT3/8″ NPT3/8″ 498 5.sixty five four.seventy one 4.24 three.seventy seven 3.three 2.eighty three two.36 1.88 1.41              
AT80 18 38.17 NPT3/8″ NPT3/8″ 664 four.fifty eight 3.eighty two three.44 three.05 2.67 2.29 one.ninety one 1.fifty three 1.34 1.15            
AT100 16 thirty.16 NPT3/8″ NPT3/eight” 830 three.sixty two three.32 3.02 two.87 two.56 two.26 1.81 1.51 1.21 1.06 .nine        
AT130 fourteen 23.09 NPT3/8″ NPT3/eight” 1079 two.seventy seven two.66 2.fifty four 2.31 two.08 one.85 one.62 one.39 one.15 .92 .eighty one .sixty nine .23      
AT170 12 twelve.44 NPT3/8″ NPT3/eight” 1411 1.49 1.forty three one.37 1.31 one.24 one.12 1 .87 .75 .sixty two .five .44 .37 .twelve    
AT240 ten eight.sixty four NPT3/8″ *HF4 1992 1.04 .99 .95 .ninety one .86 .seventy eight .69 .6 .52 .43 .35 .three .26 .22 .17  
AT300 nine 7.32 NPT1/4″ *HF4 2490 .88 .eighty four .84 .eighty one .seventy seven .seventy three .66 .fifty nine .fifty one .forty four .37 .33 .29 .33 .eighteen  
AT400 8 5.53 NPT1/4″ *HF4 3320 .sixty six .64 .64 .sixty one .58 .55 .five .44 .39 .33 .28 .25 .22 .21 .19 .fourteen

Remark one) Maxium outlet strain are at an air driven strain of 8 bar or 116 PSI ,for lengthy life utilizing

of these kinds of pump ,we advise that air driven force should be not far more than eight Bar 

Normal diagram of this kind of air pushed liquified CO2 pumps 


 

Item Applications 

 

Factory corners 

 

Usun Model: At10-CO2 50-80 Bar High Pressure Air Liquified CO2 Pump for Closed Loop System

Tags:

gear pump

As one of leading gear pump manufacturers, suppliers and exporters of mechanical products, We offer gear pump and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of gear pump

Recent Posts